POWER DISTRIBUTION (WALL MOUNT) Mac Victor Power Network (MVPN) 2.0 to 3.0kVA

THOR SYSTEMS’ MVPN (Mac Victor Power Network) combines a UL 1778 Listed centralized isolated power network with an integral UL 1778 Listed on-line UPS. The MVPN provides clean and continuous power (battery back-up) for critical electronics such as Points of Sale, Back Office, Network Rack, and Telephone Security Panels.

FEATURES

  • UL1778 2nd Edition Listed
  • Unit available in 2.0 to 3.0kVA configurations
  • Increases revenues with continuous operation for all network components of the critical electronic systems during electrical power failures and other power quality disturbances.
  • Reduces both operating and maintenance expenses from downtime due to software lockups, data losses, and hardware failures
  • Eliminates all remotely located plug-in UPS, surge strips, and filters
  • Integrated circuit breakers for up to 5 branch circuits with optional integrated IG receptacles can reduce new construction costs by eliminating the need for dedicated circuit breaker panel.
  • Wall mounted design saves vital floor space and reduces the need for under counter/desktop space
  • Bypass Switch (make before break) provides seamless power during UPS maintenance
  • Input and output power pilot lights provide for status indication and easy troubleshooting
  • True on-line double conversion UPS provides voltage and frequency regulation to support and protect mission critical applications
  • Integral shielded low impedance isolation transformer
  • 40kA input and output surge protection with EMI/RFI filtering
  • Patented Product: U.S. Patent 7,408,271 (August 5, 2008)

APPLICATIONS

  • Convenience Stores, Fast Food Restaurants
  • Gas Stations, POS Equipment, Back Office Electronics
  • Customer Kiosks, Printers, Monitors, Wastewater Treatment Controls, Location Servers/Communication Racks

OPTIONS

  • SNMP Network Card and Extended Battery configurations available

GENERAL INFORMATION:
Agency Listings UL 1778
Application Commercial
Warranty 2 Years
ELECTRICAL SPECIFICATIONS:
Output Full Load Capacity: 2.0, 3.0 kVA
Input Voltage: 120Vac, 50/60 Hz, Single-Phase, 2W + Ground
Output Voltage: 120Vac, Single-Phase, 2W + Ground
Dry Contacts: Input/output power monitoring for site automation
SERVICE CONDITIONS:
Storage Temperature Range: -55o to +85o C (-67 o to +185o F)
Operating Temperature Range: 0o to 40o C (32 o to 104o F)
Relative Humidity: 0% – 95%, Non-condensing
Operating Altitude: 0 Feet to 12,000 Feet
System Audible Noise Level: Less than ANSI C89 standard for transformers
MECHANICAL SPECIFICATIONS:
Enclosure: NEMA 1
Size: 19”W x 14”H x 10”D (without UPS)
Cable Landing: (22); ½” and ¾” EMT Knockouts
Service Access: Full Width Hinged Front Cover
Ventilation: Naturally Convection Cooled
SURGE SPECIFICATIONS:
kA Per Mode: 40kA Input and 40kA Output (with EMI/RFI Filtering
Technology: Hybrid Design
Isolation Transformer: Low Impedance, Electrostatically Shielded; 115oC Max Temp
Rise; 180oC Insulation Class; All Copper Windings; 3.3% to 4.4% Impedance; Common
Mode Nose Attenuation; Full Load Efficiency 94% to 96%
Bypass Switch: Make Before Break
PRODUCT OPTIONS:
5th Circuit Breaker Pre-wired to Receptacles on End Wall
Emergency Shutdown
Remote Power Off
PRODUCT ACCESSORIES:
MVPS-515-12 : Isolated Ground Receptacle Power Strip, 12” Long (4) IG Outlets
MVPS-515-20: Isolated Ground Receptacle Power Strip, 20” Long (10) IG
Outlets with 4’ of Seal-TiteFlex Conduit
GT-2000T: On-line UPS, 2.0 kVA GT-3000T: On-line UPS, 3.0 kVA
GT-SNMP: SNMP Communications Cable


Electrical power quality problems cost the United States industries over $100 billion annually
80% of voltage surges and transients are caused by changes in electrical demand, inside the user's facility